Article II. If all results are indicated with a green ( 0 ), no further adjustment will be necessary. If some results are indicated with a purple ( 0 ), bring that cameras gain level up by (10) using the gain level adjustment procedure mentioned above. Rerun center test until results are all indicated by
green ( 0 ). Do not exceed 75 for a gain setting on either camera. If you cannot get the results to indicate green, and gain level is at 75, change the deviation setting by (5) not to exceed (20). If you cannot achieve a green 0 indication, please call for assistance.

Saving Proper:

When nozzle center tests are indicated green (0) on wide view and narrow view cameras for all nozzle sizes, it is now necessary to save proper data back to host computer or MCS.

Once this procedure is done and the proper data has been received. It should not be necessary to carry out this procedure again. It may be necessary to verify settings after machine reset (power on reset).

Once this procedure has been set up, if results of center test are not indicated green ( 0 ), the following guide should be followed:

1. If individual nozzles are indicated purple, the nozzle AMID for that nozzle position needs cleaning.
2. If individual nozzles are indicated yellow, the nozzle AMID for the nozzle position should
    be replaced.
3. If individual nozzles are indicated red (X), the nozzle for that position should be replaced.
4. If all nozzles or all size nozzles are indicated purple, ensure that camera prism is clean, and
    replace camera high-frequency bulbs.
It will be necessary to manually change the Back-Light Tolerance values in
your machine’s proper data.

<<Prev | 1 | 2 | 3 | 4 | 5 | Next>>
 
SMT Research Inc.
37575 North Hwy 59
Lake Villa, IL 60046
Phone: (847) 587-7200
Fax: (847) 587-7851
info@smtresearch.com
SMT Research Inc.
Service Center
103 W. Washington St.
New London, IA 52645
Phone: (319) 367-5000
Fax: (319) 367-5155
Home | Overview | Contacts | Downloads | Comments
Content © 2000-2008 SMT Research, Inc. - All rights reserved
Web Development by Attilanet Corporation